Laboratory Ultrapure Water System


The Crystal EX Ultrapure systems are economy class, multi-purpose, water purification systems. All Crystal EX Systems produce two types of water : Ultrapure (ISO 3696 Grade 1) and Pure (ISO 3696 Grade 2). Ultrapure water produced by the Crystal EX systems has resistivity 18.2 Mega Ohm*cm (conductivity 0.055 µS/cm). This exceeds requirements of all the relevent standards (ISO 3696 Grade 1, ASTM Type I, CLSI Type I). Purified water is collected in a storage tank. The recirculation system ensures a consistent quality of water, and a low level of organic carbon content (TOC). TOC is <2 ppb for “HPLC” and “Bio” configurations, and 5-10 ppb for the “Trace” configuration.

The dispensing rate of high quality Ultrapure water is 2 L/min. Pure water produced by Crystal EX systems can be used for labware washing, wet chemistry methods, flame spectrophotometers, etc., Pure water is dispensed directly from the storage tank. The dispensing flow rate of pure water is 4 L/min.

GRADUS
Crystal EX Ultrapure water systems are available in the following configurations::
  • Crystal EX Trace System (P/N EX-1001-P)produces water for inorganic trace analysis. This water is recommended for atomic absorption spectrometry (with graphite furnace atomizer), ICPOES analysis, ICP-MS and other inorganic analytical methods
  • Crystal EX HPLC System (P/N EX-1101-P) produces water with very low organic carbon content (TOC) to comply with the requirements of liquid chromotography methods. Crystal E HPLC water can also be used for some microbiological and molecular biology applications
  • Crystal EX Bio System (P/N EX-1201-P) produces water with very low organic and RNase / DNase content, intended for molecular biology, including RNase - sensitive applications.
  • Low cost of ownership
  • Ideal for FTIR / KBr pellet preparation
Description EX series
Application EX-1001-P Trace EX-1101-P HPLC EX-1201-P Bio
Water Type • Ultrapur water (Grade 1)
• Pure water (Grade 2)
• Ultrapur water (Grade 1)
• Pure water (Grade 2)
• Ultrapur water (Grade 1)
• Pure water (Grade 2)
Application • Automatic absorption spectometry
• Plasma optical emission spectometry
• Other inorganic trace analysis
• Chromotography
• Mass spectometry
• Microbiology • Molecular biology
• High sensitive biology applications
Display Conductivity Sensor Monochrome LCD display Monochrome LCD display Monochrome LCD display
TOC Monitor Connection Possibility to Water Dispensing Unit
-
-
-
Storage Unit Water storage tank ‘Pro’ 30 L w/o multipoint sensor included
Installation Installation on a laboratory bench
Specification
Purified Water Specifications Crystal EX Trace Crystal EX HPLC Crystal EX BIO
Grade 1 water resistivity
Grade 1 water conductivity
18.2 MΩ x cm
0.055 µS / cm
18.2 MΩ x cm
0.055 µS / cm
18.2 MΩ x cm
0.055 µS / cm
Grade 2 water resistivity
Grade 2 water conductivity
>10 MΩ x cm
<0.1 µS / cm
>10 MΩ x cm
<0.1 µS / cm
>10 MΩ x cm
<0.1 µS / cm
Total organic carbon (TOC) level <10 ppb <5 ppb <5 ppb
RNase
DNase
N/A
N/A
N/A
N/A
<1 pg/ml
<5 pg/ml
Bacteria
Endotoxins
<0.01 CFU / ml
<0.15 EU / ml
<0.01 CFU / ml
<0.15 EU / ml
<0.01 CFU / ml
<0.001 EU / ml
Particles > 0.22 µm
Nominal flow, pure water (to storage tank)
<1 per ml
10 L/h
<1 per ml
10 L/h
<1 per ml
10 L/h
Nomial dispense flow, pure water
Deionization module life (standard module)
2 L / min
1 m³
2 L / min
1 m³
2 L / min
1 m³
Deionization module life (high capacity module)
Recovery
3 m3³
>30 %
3 m3³
>30 %
3 m3³
>30 %
Dimensions (W x D x H) cm
Feed water pressure
40 x 35 x 55
1-4 bar
40 x 35 x 55
1-4 bar
40 x 35 x 55
1-4 bar
Feed water conductivity <1500 µS / cm <1500 µS / cm <1500 µS / cm