PCI Analytics Pvt . Ltd.
Toll Free Number : 1800 266 9393

Q-Front EDI



Adrona’s product Q-Front EDI is a tap water system for general laboratory applications and inorganic analytical methods. Q-Front EDI systems are intended for use in laboratories with high daily pure and ultrapure water consumption. Q-Front EDI systems include the flexible dispenser.

Ordering information :
Model Part number
Q-Front 5 EDI Trace QF-4101
Q-Front 10 EDI Trace QF-4201
Q-Front 5 EDI HPLC QF-4103
Q-Front 10 EDI HPLC QF-4203
Q-Front 5 EDI Bio QF-4105
Q-Front 10 EDI Bio QF-4205
Description
 
Q-Front EDI Trace
Q-Front EDI HPLC
Q-Front EDI Bio
Q-Front EDI water type
  • ultrapure water (Grade 1)
  • pure water (Grade 2)
  • ultrapure water (Grade 1)
  • pure water (Grade 2)
  • ultrapure water (Grade 1)
  • pure water (Grade 2)
Application
  • atomic absorption spectrometry
  • plasma optical emission spectrometry
  • other inorganic trace analysis
  • chromatography
  • mass spectrometry
  • microbiology
  • molecular biology

 

  • highly sensitive molecular biology
  • cell culture
  • other methods sensitive to RNase and endotoxins
  • biology applications

 

Display
colour graphic LCD display
Water quality sensor
*
*
*
TOC Monitor
-
*
*
Volumetric dispense
*
*
*
Dispenser
flexible dispenser attached
Connection to Flow point
*
*
*
Storage tank
storage tank required, but not included
Installation
installable on a laboratory bench

Consumables
Part number Description Replacement criteria Comments
10410 Replacement pre-filter If the filters are clogged or every 6 months  
10030 “Polishing+” module Grade 1 water conductivity is > 0.1 μm/cm constantly or every 12 months  
10017 Sterilization UV bulb 2 years on average “Bio” configuration
10018 Photooxidation UV bulb 2 years on average “HPLC” and “Bio” configuration
10012 Replacement 0.22 μm dispense filter Every 6–12 months “Trace” and “HPLC” configuration
10120 Replacement ultrafilter Every 3–6 months “Bio” configuration
Flow diagram
Specifications
 
Q-Front EDI system configuration
 
Trace
HPLC
Bio
Grade 1 water resistivity at 25 °C
18.2 MΩ x cm
18.2 MΩ x cm
18.2 MΩ x cm
Grade 1 water conductivity at 25 °C
0.055 μS/cm
0.055 μS/cm
0.055 μS/cm
Grade 2 water conductivity at 25 °C
0.1 μS/cm
0.1 μS/cm
0.1 μS/cm
Total Organic Carbon (TOC) level
<10 ppb
<5 ppb*
<5 ppb*
RNase
-
-
<0.01 ng/mL
DNase
-
-
<4 pg/μL
Bacteria
<0.01 CFU/mL
<0.01 CFU/mL
<0.01 CFU/mL
Endotoxins
<0.15 EU /mL
<0.15 EU /mL
<0.001 EU /mL
Particles >0.22 μm
<1/mL
<1/mL
<0.05/ per mL
Feed water pressure
0.4 - 6 bar
0.4 - 6 bar
0.4 - 6 bar
Data interface
RS 232
RS 232
RS 232
Dimensions (WxDxH), cm
35x39x54
35x39x54
35x39x54
System weight, kg
27
28
29
Operation weight, kg
31
32
33